Instruction manual
Overview
2-2
Installation, SPM, Maintenance, and Troubleshooting Supplement
Environment 2
The control unit must be installed on a backboard. The placement of the 
backboard, and the control unit on it, requires careful consideration. Make sure 
you install the backboard in an area that meets all of the environmental 
requirements listed in Table 2-1.
Table 2-1.  Environmental Requirements
Parameter Value
Operating
Temperatures
40
ο
–104
ο
F (4
ο
–40
ο
C)
Optimal temperature: 60
ο
F (15.6
ο
C)
Humidity  20%–80%
Airborne
Contamination
Do not expose the control unit to moisture, corrosive 
gases, dust, chemicals, spray paint, or similar 
material.
Ventilation  Allow at least 1 inch (2.54 cm) on the right and left 
sides of the control unit and at least 12 inches 
(30.48 cm) above and below it to prevent overheating.
Do not place the control unit near extreme heat 
sources (for example: furnaces, heaters, attics, or 
direct sunlight).
Electrical Fields Do not expose the control unit to devices that 
generate electrical currents causing interference (such 
as arc welders or motors).
Heat Dissipation Basic carrier: 500 BTU/hr
Basic carrier: with one expansion carrier, 1000 BTU/hr
Basic carrier: with two expansion carriers, 
1500 BTU/hr