Board Renumbering with the 016 MLX Module
8-78
Installation, SPM, Maintenance, and Troubleshooting Supplement
Follow these steps to replace a 008 MLX module with a 016 MLX module:
1. Back up the system programming to the customer backup card. Use a 
filename that describes the pre-016 MLX configuration-for example, “pre-
016 MLX.”
2. Print a System Setup report. Determine whether the last slot/slots are 
programmed with phantom modules. If there are phantom modules, the 
programming for these modules will be removed when the new 016 MLX 
module is implemented.
3. If no phantom modules are programmed, go to Step 4. If there are phantom 
modules, print out all the Extension Information reports for the extensions 
and MFMs connected to the phantom modules. The extensions must be re-
programmed after the module is implemented.
4. Print an Extension Directory report. (This report also includes phantom 
extension numbers.)
5. Print a Group Calling Information report.
6. Print a Group Coverage Information report.
7. Print Extension Information reports for all ports (including MFMs) on the 
008 MLX module that is being replaced.
8. Power down the system and replace the 008 MLX module with the 016 
MLX module.
9. Power up the system.
This procedure adds eight additional logical IDs to the system 
configuration, starting after the first eight ports of the new 016 MLX 
module. (This occurs because you are adding eight ports to the 
system for each 016 MLX module that replaces a 008 MLX module.) 
The second set of eight ports on the 016 MLX module will acquire the 
extension numbers from the next extension module to the right in the 
system. This slippage continues for the rest of the extension modules 
in the system. You must do extensive station renumbering for the 
extensions that follow the new 016 MLX module. 