Instruction manual
Basic System Management Procedures
8-54
Installation, SPM, Maintenance, and Troubleshooting Supplement
Figure 8-9.  Pass-Thru
A Pass-Thru request must be initiated at a PC; it is not available from a UNIX 
System PC—that is, Pass-Thru cannot be established between two IS II/III 
PCs. The local admin PC must be in an idle state.
A Pass-Thru request to a locally connected IS II/III system causes the modem 
to fall back to 1200 bps if the speed is set to 2400 bps and the modem call to 
the control unit is at 1200 bps. If necessary, the system adjusts its speed to that 
of the local SPM PC.
Once the Pass-Thru connection is established, you can program in any of the 
following IS II/III applications from your SPM PC:
■ AUDIX Voice Power
®*
■ Call Accounting System
1
■ Fax Attendant System (IS III only)
■ CONVERSANT Intro (IS III only)
1 Can be ordered only as an upgrade to existing CAS installations.
SPM PC
Control Unit
IS II/III PC
Direct 
Connection
Remote
Connection