Instruction manual

PCMCIA Upgrade Card
7-15
Upgrading to MERLIN MAGIX Release 1.5
13. When the upgrade is complete, the following appears:
If the upgrade was successful:
Upgrade Successfully Completed.
Slot Busied Out.
Slot Restore Needed.
If the upgrade was not successful (for example, you chose the wrong
firmware for the module:
Upgrade Slot nn:
Board Memory Programming
Failure.
Upgrade CANCELLED.
Upgrade INCOMPLETE.
14. If the upgrade failed in Step 13, re-attempt the upgrade and choose the
correct firmware. The upgrade will fail again, staying at 00% completed,
and you will see the following error screen:
Upgrade Slot nn:
Memory on module will
not erase.
Upgrade CANCELLED.
Upgrade INCOMPLETE.
Repeat the upgrade again with the correct firmware and the upgrade will
succeed.
15. When finished, select Exit.
16. Select Restore from the Maintenance Menu.
17. Select Yes when Do you want to continue? appears.
18. Repeat Steps 2 through 16 for each module to be upgraded.
19. When the upgrades are completed, verify the application version of each
module by selecting its slot under Maintenance
SystemInventory.