Instruction manual
Upgrading from a MERLIN LEGEND System
7-12
Installation, SPM, Maintenance, and Troubleshooting Supplement
5. As necessary, add a Bridge module you need to fill up the single empty slot 
at the end of the last plastic carrier before the metal carrier. To add a Bridge 
module, select “Bridge” from the Boards screen in System Programming. 
(Bridge module programming is available in Release 1.5 or later of the 
MERLIN MAGIX system.)
6. If you are adding a 100R INA module, place it in the first slot of the metal 
carrier.
7. Add any other modules you want to the metal carrier.
8. Power up the system.
9. Perform a board renumber.
10. If you have added a MERLIN Messaging System Release 2.0 module to 
the metal carrier, you must program for it in one of the two following ways:
■ If you have chosen to use the existing Voice Mail Calling Group, add 
the extension numbers assigned to the MERLIN Messaging ports to 
this calling group. Also, add the line numbers that go to this calling 
group. As needed, enable rotary dialing.
■ Run the automatic configuration for Release 2.0 of the MERLIN 
Messaging System. (See the MERLIN MAGIX™ Integrated System 
Release 1.5 Release Notes.) As necessary, program the restriction for 
outcalling and program the lines that are to ring in the Voice Mail 
Calling Group.
You can program a Bridge module only from a PC running 
WinSPM.