Instruction manual

Tests
4-30
Installation, SPM, Maintenance, and Troubleshooting Supplement
Tests 4
Three new Tests apply to both the 100R INA and 100 DCD modules:
Line loopback
Payload loopback
Bit Error Rate Test (BERT)
Three other tests have been added specifically for the 100 DCD module:
Data-channel loopback
Data terminal loopback
Data port local loop
Line Loopback Test 4
This test loops the T1 interface back towards the network on the network side
of the framer. To perform this test, you must first busy-out the module. From
your system programming console, use the following sequence to access the
Line loopback test.
Menu: Maintenance
SlotSlot#EnterDemand testLineLpbk
If you have not busied out a module when the test requested needs to
have the module busied-out, you receive the following error message:
Failed Slot is not busied out
When this test is activated, the far end generates the test pattern using
the built-in BERT Tests or other data-generating equipment.