Error Events
4-29
100R INA and 100 DCD Modules
Menu: MaintenanceSlotSlot#EnterErrorEvents
IntervalInterval#Enter
Clear Error Events 4
The Clear event causes error events for intervals, including the current interval,
to be cleared and reset to zero. If you select a slot containing a 100 DCD
module, you can choose to clear individual intervals or all intervals. If you select
a slot containing a 100R INA module, you may clear only all intervals.
From your system programming console, use the following sequence to access
the Clear screen (be sure to select the corresponding 100R INA or 100 DCD
module slot number).
Menu:
To clear All Intervals:
Maintenance
SlotSlot#EnterError EventsClear
To clear individual intervals:
Maintenance
SlotSlot#EnterError EventsClear
IntervalEnter interval #EnterYes
Invalid intervals have all zeroes for error data, but no visual indication
is given to show that the interval is not valid. You can use the Valid
interval count on the 24-hour total screen to determine which intervals
are valid so as to distinguish how many intervals are invalid.
To stop the clear event and retain all error events press Back or
Cancel. You will return to the Error Events screen.