Instruction manual

Error Events
4-27
100R INA and 100 DCD Modules
:
Table 4-8. 24-hour total Line descriptions
Line Description
24-Hour Slot xx xx is the slot currently being reported on.
nn Valid Intervals nn is the number of valid 15-minute intervals from the
past 24 hours. Reporting on the number of valid
intervals allows you to distinguish a truly error-free
interval from one that contains zeroes due to other
reasons.
MIS, SLP, ES,
BS
Misframes (MIS), Slips (SLP), Errored Seconds (ES),
Bursty Errored Seconds (BS).
Each error figure is the sum of all error events from all
available intervals. 9999 represents an overflow
situation.
SEC, FS, BPV Severely Errored Seconds (SEC), Failed Seconds (FS),
Bipolar Violations (BPV).
Each error figure is the sum of all error events from all
available intervals. 9999 represents an overflow
situation.
You can refresh the 24-hour Total screen by pressing Back and then
pressing 24 hr total again.