Instruction manual
Error Events
4-27
100R INA and 100 DCD Modules
:
Table 4-8.  24-hour total Line descriptions
Line Description
24-Hour Slot xx xx is the slot currently being reported on. 
nn Valid Intervals  nn is the number of valid 15-minute intervals from the 
past 24 hours. Reporting on the number of valid 
intervals allows you to distinguish a truly error-free 
interval from one that contains zeroes due to other 
reasons.
MIS, SLP, ES, 
BS
Misframes (MIS), Slips (SLP), Errored Seconds (ES), 
Bursty Errored Seconds (BS).
Each error figure is the sum of all error events from all 
available intervals. 9999 represents an overflow 
situation.
SEC, FS, BPV Severely Errored Seconds (SEC), Failed Seconds (FS), 
Bipolar Violations (BPV).
Each error figure is the sum of all error events from all 
available intervals. 9999 represents an overflow 
situation.
You can refresh the 24-hour Total screen by pressing Back and then 
pressing 24 hr total again.










