Instruction manual
100R INA/100 DCD Maintenance
4-25
100R INA and 100 DCD Modules
From your system programming console, use the following sequence to access 
the 100R INA and 100 DCD modules maintenance menu (be sure to select the 
corresponding 100R INA or 100 DCD module slot number).
Menu: Maintenance
→Slot→Slot#→Enter
Table 4-7.  New Maintenance Considerations for the 100R INA and 100 
DCD Modules
Maintenance Option Description
Status The status screen provided with MERLIN MAGIX 
cannot be used to check the router portion of the 
100R INA and 100 DCD modules. You must use 
100R INA and 100 DCD management interfaces to 
determine the status of the router. 
Busy-Out When you initiate the busy-out feature, the 100R 
INA and 100 DCD modules disrupt router services 
at the module level during the time the module is 
busied-out.
Restore When the100R INA and 100 DCD modules are 
restored, router service is restored at the module 
level. 
Reset To reset a 100 DCD module, you select each of the 
two data ports or slot separately. The system 
indicates if the reset completed successfully or 
failed. When the 100 DCD module is not installed in 
the carrier, the maintenance screens do not display 
the maintenance options to busy out the data ports.