Instruction manual

100R INA/100 DCD Maintenance
4-25
100R INA and 100 DCD Modules
From your system programming console, use the following sequence to access
the 100R INA and 100 DCD modules maintenance menu (be sure to select the
corresponding 100R INA or 100 DCD module slot number).
Menu: Maintenance
SlotSlot#Enter
Table 4-7. New Maintenance Considerations for the 100R INA and 100
DCD Modules
Maintenance Option Description
Status The status screen provided with MERLIN MAGIX
cannot be used to check the router portion of the
100R INA and 100 DCD modules. You must use
100R INA and 100 DCD management interfaces to
determine the status of the router.
Busy-Out When you initiate the busy-out feature, the 100R
INA and 100 DCD modules disrupt router services
at the module level during the time the module is
busied-out.
Restore When the100R INA and 100 DCD modules are
restored, router service is restored at the module
level.
Reset To reset a 100 DCD module, you select each of the
two data ports or slot separately. The system
indicates if the reset completed successfully or
failed. When the 100 DCD module is not installed in
the carrier, the maintenance screens do not display
the maintenance options to busy out the data ports.