Instruction manual

Central Office Provisioning
Standard BRI Operation Provisioning
The attributes in the following table must be set as indicated for all MERLIN LEGEND BRI
system installations. These attributes can be found on screens 2.3,4, and 5 of Recent
Change view 23.8.
Table 1. Installation: Standard BRI Operation Mandatory Provisioning
Attribute Name
Value
Recent Change
Notes
NT1TYPE AULC
23,8 Screen 2 Line Coding is 2B1Q
(U interface)
DSL CLS
MP
23.8 Screen 2 Class of Service is
multipoint
MTERM
2
23.8 Screen 2 Maximum number of
terminals on DSL
MAXB CHL
1
23,8 Screen 3
Maximum number of
channels per terminal
ACT USER Y 23.8 Screen 3
Actual user
CKT LCC
DS1*
23.8 Screen 4 DS1 = Circuit-Switched
Service
TERMTYP TYPED 23.8 Screen 4
Type ā€˜D’ terminal being
emulated
*
The actual name "DS1" for the Line Class Code maybe different depending on the central
office. The name is not relevant for MERLIN LEGEND BRI system provisioning, but the standard
configuration for the Line Class Code used as the parameter for the CKT LCC must be set as
follows for proper operation:
Attribute Name
Value Recent Change
===========
====
==============
Class of Service
ISDN 4.1 Screen 1
Terminating Treatment
INDIV
4.1 Screen 1
4 Basic Rate Interface (BRI) Provisioning Guide