Instruction manual

System Testing and Verification
13.
Test One-Touch provisioning. (This test is valid only if a line can receive incoming
calls.)
a.
b.
c.
d.
e.
f.
Pre-select line 1 on station A and lift the receiver (go off-hook) and then hang
up.
Place a call from station B to line 1 on station A.
Allow the call to ring at station A but do not answer the call.
Hang up at station B.
Place another call from station B to line 1 on station A.
You can hear ringback on station B and ringing at station A.
If you hear a busy signal at station B and station A does not ring, write “n” in
the “One Touch” column of the planning form and record the
audio results in the “Comments” column,
Repeat this test for all other BRI lines on station A.
14. Test CO Transfer. (This test is valid only if calls can be placed and received from
the line, and if service is subscribed from the local central office.)
a.
b.
c.
d.
e.
f.
Place a call from station B to line 1 on station A. Answer the call at station A.
The transfer source is an incoming call to station A.
Press Transfer.
— The green LED on station A is fluttering.
Press the BRI Access button,
— The red and green LEDs next to the BRI Access button are steadily lit and
you hear dial tone.
If the test fails, write “Inactive” in the “BRI Acc” column on the planning form
and describe the status of the LEDs.
Dial the digits for station C’s DN.
— You hear ringback at station A and ringing at station C.
Answer the call at station C.
Press Transfer on station A.
— Stations B and C are connected.
If not, the transfer was not completed, Write “n” in the “Inbound Source”
column. Check that station A is still connected to station C. Then reconnect
to station B by selecting the button next to the fluttering green LED, Check
that station A is now disconnected from station C (the green LED is off) and
connected to station B (the green LED is on).
Station A is disconnected from both B and C. The green LEDs next to the BRI
Access button and next to the button used to call station B are off.
If not, write “n” in the “A Disconnected from B and C“ column of the
planning form,
22 Basic Rate
Interface (BRI) Provisioning Guide