Instruction manual

System Testing and Verification
7. Wait for the red LED on the processor module to go off. (The red LED on each 800
CO-BRI module should be on indicating no service on each port.
8. Perform diagnostic tests on each module:
a.
b.
c.
Internal Ioopback test
Board controller test
B-channel Ioopback test
Put the module out-of-service by busying it out:
(1).
Press Menu Maintenance.
(2).
Press slot.
(3)
0
Enter the slot number of the module.
(4).
press
Enter
Busy
Out
Yes.
(5). Wait for the busy-out to complete,
(6).
Press
Exit.
Execute the tests:
Press Demand Test
IntLoopback
Test Once.
Wait for the test to complete.
If the test passes, press
Exit
Exit
and continue with the
next test. If the test fails, follow the procedure in step 8d
below to remove the module.
Press
BoardCntrlr
Test Once.
Wait for the test to complete.
If the test passes, press
Exit
Exit
and continue with the
next test. If the test fails, follow the procedure in step 8d
below to remove the module.
Press
BchLoopback.
Wait for the test to complete.
If the test passes. press Exit + Exit and continue with the
next test. If the test fails, follow the procedure in step 8d
below to remove the module.
Press
Exit.
(l).
(2).
(3).
(4).
(5).
(6).
(7).
(8).
(9).
(10).
Put the module back in service:
(1).
Press
Restore
Yes.
(2). Wait for the restore to complete.
(3). If more modules require testing. press Exit+ Exit and repeat from step
8a(3) above. When all modules have been tested, press Home.
14 Basic Rate Interface (BRI) Provisioning Guide