Instruction manual

System Testing and Verification
Requirements
Prior to installation of the system, the systems technician or consultant must acquire
the following information:
Letter of Agency from the customer
Contact number at the central office for troubleshooting
MERLIN LEGEND and MERLIN LEGEND BRI System Planning forms
The following equipment is necessary for testing BRI lines:
Testing
MERLIN LEGEND BRI system with the BRI Feature module
Three MLX display telephones
A telephone with existing access to the central office
One or more 800 CO-BRI modules (a maximum of five can be installed
depending on the power supply)
BRI lines with SPIDs and DNs provided by the 5ESS central office and USOP
configuration parameters
A Tektronix Craftek Model CT100 (recommended) for troubleshooting lines
ISDN telephone with an NT1 interface
To ensure ease of programming and minimize human error, it is recommended that
testing for correct operation of the BRI line and the system be performed on the
MERLIN LEGEND BRI system in its default state with minimal system programming. After
completion of testing, the system can be configured to meet customer needs as
indicated by the system planning forms with the assurance that the BRI lines will
function reliably.
Use the following steps as a guideline to install and test the MERLIN LEGEND BRI
system. Refer to the MERLIN LEGEND Communications System Installation manual (555-
620-141 ) and the MERLIN LEGEND Basic Rate Interface Supplemental Reference (555-
601-111 ) for complete installation instructions and cautions.
1.
2.
3.
4.
5.
6.
If upgrading an existing MERLIN LEGEND system, backup the current customer
translations on a diskette.
Turn the system off.
Install the 800 CO-BRI modules (maximum of five, three per carrier) in the system
leaving no empty slots before the last module.
Turn the system on.
Wait for the red LED on the processor module to go off.
Frigid start the system,
Basic Rate Interface (BRI) Provisioning Guide 13