Instruction manual

MERLIN LEGEND Communications System Release 5.0
System Planning
555-650-112
Issue 1
June 1997
Unit Load Calculation
Page F-4
F
6. Calculate the actual carrier unit load.
If the total actual unit load is less than or equal to 54 (391A1 or 391A2
power supplies) or less than or equal to 75 (391A3 power supply), no fur-
ther calculation is required.
If the total actual unit load is more than 54 (391A1 or 391A2 power sup-
plies) or more than 75 (391A3 power supply), continue to Step 7.
Module Qty x Unit
Load
= Total
008 12.0
008 MLX 13.25
008 OPT 8.0
012 8.4
016 12.8
100D 0.0
400 0.0
400 EM 8.0
400 GS/LS/TTR 0.0
408 12.0
408 GS/LS 12.0
408
GS/LS-MLX
13.5
800 0.0
800 GS/LS 0.0
800 DID 8.0
800 GS/LS-ID 8.0
MERLIN LEGEND Mail 0.0
Total Estimated Unit Load
If total is less than 54 (for the 391A1 or 391A2 power supplies) or 75
(for the 391A3 power supply), no further calculation is required.
If total is 54 (391A1 or 391A2 power supplies) or 75 (391A3 power sup-
ply) or more, continue to Step 6.