Instruction manual

Preparation
Location of the Control Unit
Before installation, choose a room, closet, or other area where the system
control unit can be mounted on the wall. The area must meet the environmental
requirements in Table 1-1.
Table 1-1 Environmental Requirements
Distances
Within 25 feet of the network interface (cannot be installed
outdoors)
Within 1000 feet of telephones
Within 5 feet of a dedicated AC power outlet (1 plug
per carrier)
Heat
Fully loaded basic carrier: 500 Btu/hr
Dissipation
Fully loaded 2-carrier: 1000 Btu/hr
Fully loaded 3-carrier:
1500 Btu/hr
Power
Basic carrier: 117 VAC 60 Hz ± 1%
160 W 3 amps
Requirements
2-carrier: 117 VAC 60 Hz ± 1%
320 W 6 amps
3-carrier: 117 VAC60HZ ± 1%
480 W 9 amps
1 properly grounded plug needed per carrier
Additional outlets if installing printers
and PCs
Temperature
40°-I04°F; 4°-40°C (optimum temperature 60°F, 16°C)
Humidity 20% - 80% relative humidity
Ventilation
Allow at least 1 inch of space on the right and left sides of
the control unit and 12 inches above and below the
control unit to prevent overheating.
Continued
Location of the Control Unit
1-5