Instruction manual
Key System Form 3c, Continued
ISDN-PRI Facility Options
Module
Slot No.
Telephone Number Telephone Number to Send
Logical ID
Line No.
(up to 12 digits)
(up to12 digits)
Test Telephone Number (up to 12 digits)
Terminal Equipment Identifier (TEl)
❑ 0 ✦
❑
(1-63)
Timers and Counters
Factory Setting
Change To
T200 Timer
1 second
(1000-3000ms)
T203 Timer
30 seconds
(1-60 seconds)
N200 Counter
3 transmissions
(1-5 transmissions)
N201 Counter
260 octets (16-260 octets)
K Counter
7 frames (1-15 frames)
T303 Timer
4 seconds
(4-12 seconds)
T305 Timer
4 seconds
(4-30 seconds)
T308 Timer
4 seconds
(4-1 2 seconds)
T309 Timer 90 seconds
(30-120 seconds)
T310 Timer
10 seconds
(2-10 seconds)
T313 Timer
4 seconds
(4-12 seconds)
T316 Timer
120 seconds
(3-120 seconds)
✦ 
Factory Setting
3