Specifications
Environmental Requirements
Control Unit
Fully loaded basic carrier
45 lbs
14” W x 23” H x 12” D
Fully loaded 2-carrier
90 Ibs
25” W x 23” H x 12” D
Fully loaded 3-carrier
135 Ibs 37” W x 23” H x 12” D
Mean Time Between Failures
2.1 years
(mean or average time the
product/system is expected
to operate before any type of
failure occurs)
Mean Time Between Outages
4.0 years
(mean or average time the system
is expected to operate before a
failure affecting more than 25%
of stations or lines for more than
15 seconds occurs)
Backboard
Without
SYSTIMAX™
■
Small system
4’ W x 3’ H x 3/4” D
■ Large system
6’ W x 3’ H x 3/4” D
With SYSTIMAX
■
Small system
5’ W x 4’ H x 3/4” D
■ Large system
7’ W x 4’ H x 3/4” D
Backboard Mounting Hardware Requirements
Wood surface
Wood screws
Concrete surface, brick, cinder block
Masonry anchors
Plaster, plasterboard
Toggle bolts
Sheet-metal surface
Sheet-metal screws
■
Hardware should have a combined pullout force of 650 Ibs.
■
When mounting to sheet-metal walls, attach to structural
members.
Location
■
Within 5 ft of dedicated AC power outlet (1 plug per carrier)
■
Within 1000 cable feet of telephones
Heat Dissipation
Fully loaded basic carrier
500 Btu/hr
Fully loaded 2-carrier
1000 Btu/hr
Fully loaded 3-carrier
1500 Btu/hr
Power Requirements
Basic carrier 117 VAC
60 Hz ± 5% 3A
2-carrier
117 VAC
3-carrier
60 Hz ± 5% 6A
117 VAC
60 Hz ± 5% 9A
Page 2