Specifications

Specifications
Capacity:
8 T/R
stations*
on 2-way voice transmission path
with support
for telephones with message-waiting LEDs;
2 TTRs
Notice to Telco:
Meets FCC Class C
Ringing current:
105-Vrms, 30-Hz sinusoidal ringing
superimposed on -48 VDC; a ring generator must be installed
in the power supply module of each carrier that has a
008 OPT module.
REN:
< 1.0 per port
Disconnect signal:
900 ms (T/R short for answering
machines, G3 fax, etc.)
Switchhook flash detection:
300-1200 ms
Loop resistance:
Serves 2-wire loops to 1300 ohms,
including stations
Capacity:
12 T/R stations on 2-way voice transmission path
with support for telephones with message-waiting LEDs, 2
TTRs
Power:
21-VDC, 600-ohm battery source
Ringing current:
105-Vrms, 30-Hz sinusoidal ringing
superimposed on -48 VDC; a ring generator must be installed
in the power supply module of each carrier that has a 012
module.
REN:
< 1.0 per port
Disconnect signal:
900 ms (T/R short for answering
machines, G3 fax, etc.)
Switchhook flash detection:
300-1200 ms
* The system recognizes the OPT module as an 012 module
having 12 ports. However, the OPT module has only 8 jacks.
Therefore, each installed OPT module decreases the system’s
capacity by 4 ports.