Instruction manual

Features
At a Glance
(continued)
Factory Settings
100D Module
Type of Facility
T1
Framing Format D4 compatible
Line Coding
AMI-ZCS
Signaling Robbed-Bit Signaling (RBS)
Line Compensation
1 (range 1-5)
1 = 0.6 dB loss
2 = 1.2 dB loss
3 = 1.8 dB loss
4 = 2.4 dB loss
5 = 3 dB loss
Clock Synchronization Source
Loop
Primary Clock First 100D module in control unit
Clock
Active
Type of CSU equipment
Foreign Exchange
PRI
Telephone Number assigned
to PRI facility 0 digits
B-channels assigned to group
None
Type of outgoing network
service per B-channel group
None
Copy telephone number from
network use PRI number
Do Not Copy
Telephone number to send to
network for outgoing PRI calls
0 digits
Test trunk telephone number
for each 100D module
None
Timer and counter thresholds
for each 100D module
T200 Timer
1 second (range 1000—3000 ms)
T203 Timer
30 seconds (range 1—60)
N200 Counter
3 transmissions (range 1—5)
N201 Counter
260 octets (range 16—260)
K Counter 7 frames (range 1—15)
T303 Timer
4 seconds (range 4—12)
T305 Timer
4 seconds (range 4—30)
T308 Timer
4 seconds (range 4—12)
T309 Timer
90 seconds (range 30—120)
T310 Timer
10 seconds (range 2—10)
T313 Timer
4 seconds (range 4—12)
T316 Timer
120 seconds (range 30—120)
Continued on next page
350 Primary Rate Interface (PRI)