Instruction manual
Features
runs every day at 3:00 a.m., comparing the application database to the switch
programming and bringing the two into agreement. The program makes
changes, as necessary, only to the application database, according to the rules
listed in Table 20. It does not change the switch programming.
Table 20. Database Reconciliation Rules
Extension appears in...
Switch
Application Database
yes yes
yes
no
no
yes
(regular extension)
no
yes
(special extension)
yes
yes
(special extension)
Action
None.
Extension is added to database. Can be added as
AUDIX Voice Power or AUDIX Voice Power/FAX
Attendant subscriber through Extension Directory
screen.
Extension is deleted from database and removed as an
AUDIX Voice Power or AUDIX Voice Power/
FAX Attendant subscriber.
Extension is retained as special-purpose extension
in database.
Extension is converted from special-purpose extension
to regular extension in database.
Platform Requirements
IS-III is delivered already installed and configured with the applications ordered.
The system consists of an AT&T Master Controller II+ or Master Controller III
running UNIX® System V Release 3.2.2. Various hardware configurations are
available; see the Integrated Solution III Installation and Maintenance Guide for
details.
For AUDIX Voice Power, an 012 module (with a ring generator) is required in the
system to provide the tip/ring interface.
The number of voice channels required for AUDIX Voice Power depends on the
number of incoming trunks, the number of subscribers programmed for the
system, and the number of busy-hour calls. Table 21 shows these
requirements.
Integrated Administration 237