Installation guide
CIB 2872
(170A) EXTRA-ALERT/2-LlNE POWER FAILURE CARTRIDGE TYPE III (6103)
This cartridge (Figure 1) is in-
tended for use with the Models
206 and 410 communications
system, and provides two sepa-
rate functions. When properly
connected to an external
alerting device (e.g., bell or
horn), it provides a loud ringer
for noisy or remote locations.
The alert sounds whenever an
outside line rings. The cartridge
also contains two jacks for
plugging in standard modular
telephones (desk models) that
3.
4.
can be used during a commer-
cial power failure.
Slide the cartridge into the
control unit cartridge slot
marked Cartridge Type III
as shown in Figure 3.
Push the cartridge slowly
and steadily until the ridge
on the front of the car-
tridge is aligned with the
front panel of the control
unit.
Note:
Certain older exter-
nal alerts require a
452A Control
Switch.
Figure 2
Figure 1
INSTALLATION INSTRUCTIONS
Warning:
Unplug the con-
trol unit from
the ac outlet be-
fore inserting or
removing the
cartridge.
1.
Open the control unit door.
2.
Grasp the plastic cover
plate in the bottom right
section of the control unit
panel marked Cartridge
Type III and pull to remove
it as shown in Figure 2.
5.
6.
7.
8.
9.
Plug the control unit power
cord into a 117-volt ac
electrical outlet not con-
trolled by a switch.
Insert the modular plug
from your standard modu-
lar power failure tele-
phone(s) into the modular
jack connector(s) A or B on
the cartridge under the
panel marked Power Fail
Lines.
Warning:
Do NOT plug
electronic voice
terminals into
these jacks.
Remove the plastic hole
plug from the Extra-Alert
jack on the cartridge and
plug the modular cords
(D4CH) into the Extra-Alert
jack.
Install the extra alert ac-
cording to the instructions
packed with the compo-
nent.
Close the control unit door.
Figure 3
Equipment manufactured by AT&T Technologies in the U.S.A.