Specifications
Electrical
■
10 Watts (35 BTUs/hour) per 400 module, normal and maximum power consumption
Specifications
■
65 Watts (225 BTUs/hour) per 206 module during normal operation
■ 100 Watts (350 BTUs/hour) per 206 module during maximum power consumption
■ U.S., Canada, and other 110V countries: 4 Amps maximum current at full system capacity
(processor module and four 206 modules)
Countries using 220V: 2.2 Amps maximum current (processor module and four 206 modules)
■
4-day memory backup (96 hours)
Processor Module
■
68000 microprocessor, 128Kbytes RAM, 512Kbytes ROM
Specifications
Extension Jack
■ Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping
Specifications
■
35- to 38-Volt talk battery
■ Ringing frequency: 20 Hz
PAGE Jack
■
Draws current on inner wire pair
Specifications
■ Provides contact closure on outer wire pair
■
600 Ohm impedance
SMDR Output
■
1200 baud
Format
■
No parity
■
8 data bits
■
2 stop bits
■
XON/XOFF protocol
■
Carriage return
■
Line feeds
Environmental
■ Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
Requirements—
Control Unit
■ Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded
electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords
■ Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight
■
Humidity 15%–90%, noncondensing
■
For proper ventilation and easy replacement of modules, provide at least 6“ (15.2 cm) clearance
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
■ Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
■ U.S. and Canada: 90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at
Requirements
15 Amps
Other countries: 90–264 VAC, fused at 10 Amps
■ Outlet must not be controlled by an on/off switch
■ Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation
material and thickness to the grounded and ungrounded branch circuit supply conductors,
except that it is green with or without one or more yellow stripes, is to be installed as part of the
circuit that supplies the product or system.
B. The grounding conductor mentioned in item A is to be connected to ground at the service
equipment.
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
grounding type, and the grounding conductors serving these receptacles are to be connected
to earth ground at the service equipment.
A-2 Specifications