Specifications
Building Wire
14 gauge/2 conductor. With bare copper ground. 450 ft.. 15 amp, 600 volt. 90
degree C temp rating (with ampacity limited to that for 60 degree C conduc-
tors). THHN insulated conductors PVC jacket. White jacket. Typical use: switch
outlet. Don’t use in outdoor location or damp basements. UL listed. Bulk reel.
Stock Mfr. Unit of Order Unit
No. No. Meas. Multiple Wgt. Price
3236353 28827472 RL450 1 30 0.69
Building Wire
10 gauge/3 conductor. With bare copper ground. 200 ft.. 30 amp, 600 volt. 90
degree C temp rating (with ampacity limited to that for 60 degree C conduc-
tors). THHN insulated conductors PVC jacket. Orange jacket. Typical use:
cloths dryer, oven/range. Don’t use in outdoor location or damp basements. UL
listed. Bulk reel.
Stock Mfr. Unit of Order Unit
No. No. Meas. Multiple Wgt. Price
3235967 63948472 RL200 1 36 1.69
Building Wire
10 gauge/2 conductor. With bare copper ground. 350 ft.. 30 amp, 600 volt. 90
degree C temp rating (with ampacity limited to that for 60 degree C conduc-
tors). THHN insulated conductors PVC jacket. Orange jacket. Typical use:
cloths dryer, oven/range. Don’t use in outdoor location or damp basements. UL
listed. Bulk reel.
Stock Mfr. Unit of Order Unit
No. No. Meas. Multiple Wgt. Price
3235991 28829072 RL350 1 43.3 1.19
Building Wire
10 gauge, 2 conductor. With bare copper ground. 30 amp, 600 volt. 90 degree
C temp rating (with ampacity limited to that for 60 degree C conductors).
THHN insulated conductors, PVC jacket. Orange. Typical use: 1,650-7,000
watts up to 30 amps. Don’t use in outdoor locations or damp basements. UL
listed. Spool.
Stock Mfr. Unit of Order Unit
No. No. Size Meas. Multiple Wgt. Price
31673 28829055 250’ BX250’ 1 34 1.19
Building Wire
14 gauge, 3 conductor. With bare copper ground. 250 ft.. 15 amp, 600 volt. 90
degree C temp rating (with ampacity limited to that for 60 degree C conduc-
tors). THHN insulated conductors, PVC jacket. White. Typical use: ceiling fan/
light switch, 3-way switch. Don’t use in outdoor locations or damp basements.
UL listed. Coil.
Stock Mfr. Unit of Order Unit
No. No. Meas. Multiple Wgt. Price
30239 63946855 CL250 1 22 0.69
Building Wire
12 gauge, 3 conductor. With bare copper ground. 250 ft.. 20 amp, 600 volt. 90
degree C temp rating (with ampacity limited to that for 60 degree C conduc-
tors). THHN insulated conductors, PVC jacket. Yellow. Typical use: ceiling fan/
light switch, 3-way switch. Don’t use in outdoor locations or damp basements.
UL listed. Coil.
Stock Mfr. Unit of Order Unit
No. No. Meas. Multiple Wgt. Price
30240 63947655 CL250 1 30 1.09
Building Wire
10 gauge, 3 conductor. With bare copper ground. 250 ft.. 30 amp, 600 volt. 90
degree C temp rating (with ampacity limited to that for 60 degree C conduc-
tors). THHN insulated conductors, PVC jacket. Orange. Typical use: clothes
dryer, oven range-up to 30 amp. Don’t use in outdoor locations or damp base-
ments. UL listed. Coil.
Stock Mfr. Unit of Order Unit
No. No. Meas. Multiple Wgt. Price
31538 63948455 CL250’ 1 45 1.69
Building Wire
8 gauge, 3 conductor stranded. With bare copper ground. 40 amp, 600 volt. 7
strand conductors. 90 degree C temp rating (with ampacity limited to that for
60 degree C conductors). THHN insulated conductors, PVC jacket. Black.
Typical use: oven/range-up to 40 amps. Don’t use in outdoor locations or
damp basements. UL listed. Coil.
Stock Mfr. Unit of Order Unit
No. No. Size Meas. Multiple Wgt. Price
32445 63949202 125’ CL125 1 34 1.59
Building Wire
6 gauge, 3 conductor stranded. With bare copper ground. 55 amp, 600 volt. 7
strand conductors. 90 degree C temp rating (with ampacity limited to that for
60 degree C conductors). THHN insulated conductors, PVC jacket. Black.
Typical use: double oven- up to 50 amps, double oven/ range-up to 55 amps.
Don’t use in outdoor locations or damp basements. UL listed. Spool.
Stock Mfr. Unit of Order Unit
No. No. Size Meas. Multiple Wgt. Price
32446 63950002 125’ CL125 1 42 2.19
ELECTRICAL & SUPPLIES
655