Instruction manual

Maintenance
Step
Screen Display
Procedure
5
slot xx:
Make a selection
Status Demand Test
Busy-Out
Reset
Restore Clock
BchLoopback
Exit
You return to the menu for that slot.
Select Demand Test.
6
Demand Test Slot xx:
Make a selection
Note:Busy out slot first
BoardCntrlr
IntLoopback
Exit
At the Demand Test SIot screen,
select IntLoopback.
7
Demand Test Slot xx:
Board 800 CO-BRI
Internal Loopback:
Test Once
Repetitive
Exit
Select Test Once for a single testing
Or Repetitive for repeated testing.
8
Demand Test Slot xx:
The internal Loopback Test in
Board 800 CO-BRI
Progress screen appears. The test
Internal Loopback Test
takes approximately one minute to
in Progress
run.
Exit
9 Demand Test Slot xx:
If the test is successful, you receive a
Board 800 CO-BRI
“Successfully Completed” message.
Internal
Loopback Test
Successfully Completed
Exit
6-6
Demand Tests