Technical information

Administering Features of the DEFINITY G3V3 and
Later, Including DEFINITY ECS
12-10 Issue 7 June 2001
Originating Extension
This is a dynamic field that is displayed only whenever the SVN
Station Security Code Violation Enabled field is set to y. Whenever
a Station Security Code Security Violation Notification Referral call
is made, the extension in this field is internally the originating
extension. It has no other significance than that it is not available for
use as a normal extension. Enter any unassigned extension
containing five digits.
Referral Destination
This is a dynamic field that is displayed only whenever the SVN
Station Security Code Violation Notification Enabled field is set to y.
Whenever a Station Security Code SVN Referral call is made, it is
made either to the extension (if provided) in this field or to the
attendant (if the field contains attd). If the destination is a station,
and if the Announcement Extension field is set to blank, the
destination must be equipped with a display module. Enter one of
the following: an assigned extension containing 5 digits or attd for
attendant.
Station Security Code Threshold
This value in this field functions in conjunction with the value in the
Time Interval field. The value in the former field indicates a
noteworthy count of invalid attempts in using Station Security Codes
which, if exceeded within the time period indicated in the latter field,
constitutes a security violation. Whenever this occurs, a Station
Security Code Violation Notification Referral call is made. Also,
invalid attempts are logged, but they are ignored unless the count of
such attempts exceeds the administered threshold. This is a
dynamic field that is displayed only whenever the SVN Station
Security Code Violation Notification Enabled field is set to y. Enter a
number between 1 and 255. Default is 10.
Time Interval
This value in this field functions in conjunction with the value in the
Station Security Code Threshold field. The value in the latter field
indicates a noteworthy count of invalid attempts in using Station
Security Codes which, if exceeded within the time period indicated
in the former field, constitutes a security violation. Whenever this
occurs, a Station Security Code Violation Notification Referral call is
made (unless this capability has been suppressed). This is a
dynamic field that is displayed only whenever the SVN Station
Security Code Violation Notification Enabled field is set to y. Enter a
value from 0:01 to 7:59. The first digit represents the hour, and the
second and third digits represent the minutes. Default is 0:03.