Technical information

Issue 7 June 2001 11-1
11
Remote Access Example
(DEFINITY ECS, DEFINITY G1,
G3, and System 75)
This chapter provides procedures for setting up and disabling Remote Access for
DEFINITY ECS, DEFINITY G1, G3, and System 75.
Setting Up Remote Access
For DEFINITY ECS, DEFINITY G1, G3, and System 75, use the example below
to set up Remote Access to help prevent unauthorized use. This example creates
a new ARS/AAR networking plan in a separate Partitioned Group Number (PGN)
for Remote Access only. By using the ARS/ARS Analysis table that corresponds
with the Remote Access PGN, you can easily control the numbers that are
allowed and the numbers that are disallowed.
1. Enter
change remote-access to display the Remote Access screen.
2. Enter
7 in the Barrier Code Length field.
3. Enter
n in the Authorization Code Required field.
4. Select a 7-digit random number and enter it into the first Barrier Code field.
5. Select a unique COR (
0 through 63, or 0 through 95 for G3) that is not used
for any facility other than Remote Access. For this example, we will use
63.
6. Enter the COR in the first COR field corresponding to the barrier code you
entered in step 4. For example, we would enter 63 in the first COR field.
7. Select a unique COS (
0 through 15) that is not used for any facility other
than Remote Access, and does not allow console permissions. For this
example, we will use
15.
8. Enter the COS in the first COS field corresponding to the barrier code you
entered in step 4. For example, we would enter 15 in the first COS field.
9. Use
change cor 63 (or the number of the COR you selected in step 5) to
administer the COR screen as shown in steps 10 through 12.
10. Enter 0 in the FRL field.