Technical information
MERLIN LEGEND/MAGIX Toll Fraud
Issue 7 June 2001
5-41
Whether or not the dialed digits are correct, an inter-digit time-out occurs
during the first attempt. The system processes only the valid number of
digits. So if a hacker enters four digits and the length is four digits, he or
she hears dial tone. If a hacker enters four digits and keeps entering more,
the system uses the time-out to hide the correct number of digits from the
hacker. The time-out recurs until the caller has dialed the eleventh digit—
giving the impression that additional digits are required—even if the barrier
code length is shorter.
SMDR registers 16 zeros for any remote access calls in which three failed
attempts have occurred.
Trunk to Trunk Transfer
This section contains instructions to allow or disallow trunk-to-trunk transfer at
each extension.
If trunk-to-trunk transfer is disallowed on an extension in a private network, the
extension cannot transfer an outside call to a local system trunk connected to the
PSTN. See the Network Reference for more information.
Trunk-to-trunk transfer may only be performed on ground-start trunks and
loop-start trunks with reliable disconnect. As of Release 4.0, trunk-to-trunk
transfer may be performed on BRI, Tie lines, PRI, ground-start trunks, and
loop-start trunks that have reliable disconnect.
Trunk-to-trunk transfer is factory set to disabled and may be enabled for a specific
extension. Single-line telephones are restricted from completing a trunk-to-trunk
transfer.
Toll Fraud Investigation: Disallow List
Information
3
General Information
Hierarchy of ways to restrict an extension:
FRL takes precedence over everything, except marked system speed
dials.
Marked system speed dial takes precedence over anything.
Allow list takes precedence over call restrictions (outward, toll,
unrestricted).
Disallow list takes precedence over an allow list.
“Pauses” (p =wildcard): Have always been available on Legend disallow lists.
3. Published 8/8/00; Reviewed for accuracy by Sue Fulmer, Tier III Senior Engineer.