Technical information
Large Business Communications Systems
4-64 Issue 7 June 2001
INADS: The INADS (Initialization and Administration System)
port
EIA: Other EIA ports
The following abbreviations are used for DEFINITY G3r:
SYSAM-LCL: Local administration to Manager 1
SYSAM-RMT: Dial up port on SYSAM board, typically used
by services for remote maintenance, and used by the switch
to call out with alarm information.
SYS-PORT: System ports accessed through TDM bus.
MAINT: Ports on expansion port networks maintenance
boards, used as a local connection for on-site maintenance.
EXT: The extension assigned to the network controller board
on which the failed login session was attempted. This is
present only if the invalid login attempt occurred when
accessing the system via a network controller channel.
The Remote Access Violations Status Report has the following fields:
— Date: The day that the invalid attempt occurred
— Time: The time the invalid attempt occurred
— TG No: The trunk group number associated with the trunk where the
authorization code attempt terminated
— Mbr: The trunk group member number associated with the trunk
where the authorization code attempt terminated
— Ext: The extension used to interface with the Remote Access
feature
— Barrier Code: The incorrect barrier code that resulted in the invalid
access attempt (G3V3 and later)
In DEFINITY G3V3 and later, the Authorization Code Violations Status
report has the following fields:
— Date: The day that the violation occurred
— Time: The time the violation occurred
— Originator: The type of resource originating the call that generated
the invalid authorization code access attempt. Originator types
include:
Station
Trunk (other than a trunk assigned to a Remote Access trunk
group)
Remote Access (when the invalid authorization code is
associated with an attempt to invoke the Remote Access
feature)
Attendant