Technical information

Large Business Communications Systems
4-56 Issue 7 June 2001
To review and verify the entries, enter list aca-parameters.
Enter change trunk group to display the Trunk Group screen.
Enter y in the ACA Assignment field.
Establish short and long holding times. The defaults are 10 seconds (short
holding time) and one hour (long holding time).
To review an audit trail of the ACA referral call activity, enter list
measurements aca.
For DEFINITY G2 and System 85:
Use PROC285 WORD1 FIELD5 and PROC286 WORD1 FIELD1 to enable
ACA system-wide.
Use P120 W1 to set ACA call limits and number of calls thresholds.
Choose the appropriate option:
To send the alarms and/or reports to an attendant, use
PROC286
WORD1 FIELD3
.
BCMS Measurements (DEFINITY ECS and
DEFINITY G1 and G3 only)
For DEFINITY ECS, DEFINITY G1 and G3, BCMS Measurements report traffic
patterns for measured trunk groups.
For DEFINITY ECS and DEFINITY G1 and G3:
Use change trunk-group to display the Trunk Group screen.
In the Measured field, enter internal if you have only BCMS or both if you
have BCMS and CMS.
Use change system-parameters feature to display the Features-Related
System Parameters screen.
Enter half-hour in the BCMS Measurement Interval field.
To review the measurements, use list bcms trunk.