System information

Assign a Data Link
Issue 1 October 1997
3-17
256 Word 2
Administer the DCIU link BX.25 level-2 timers and counters.
Press and .
256 Word 3
Administer the DCIU link BX.25 level -3 timers and counters.
Press and .
1. From Worksheet D: Assign the Data Link.
1. From Worksheet D: Assign the Data Link.
Field Manager II Field Name Enter
1 Link (DCIU physical link) [I
NTUITY AUDIX
system link # (1-8)]
1
2 Retransmission Timer 1
3 Idle Timer 10
4 Maximum Retransmissions 2
5 Maximum Unacknowledged Frames 7
Field Manager II Field Name Enter
1 Link (DCIU physical link) [I
NTUITY AUDIX
system link # (1-8)]
1
2 Activity Timer 180
3 Acknowledgment Timer 20
4 Interrupt Timer 180
5 Reset Timer 8
6 Restart Timer 8
10 Maximum Unacknowledged Packets 4
CHANGE EXECUTE
CHANGE EXECUTE