System information

Assign a Data Link
Issue 1 October 1997
3-11
026 Word 3
Administer the ACD split member characteristics.
Press and after each entry.
Repeat Fields 2 and 3 to add the other members of the I
NTUITY AUDIX system
split.
NOTE:
Error code 88 is displayed when the member extension number is not
assigned to the I
NTUITY AUDIX system machine number in Procedure 000
Word 2, Field 9. Assign a machine number first.
Assign a Data Link
The data link is the connection from the INTUITY system cabinet to the switch Data
Communications Interface Unit (DCIU) that enables nonvoice (data) messages to
pass between the I
NTUITY AUDIX system and the switch. A Generic 2 or
System 85 switch requires one link on a DCIU to be administered for the I
NTUITY
AUDIX system.
This section describes how to busy out the DCIU, assign the link, administer the
switch maintenance port, release-busy the DCIU, test the DCIU links, and check
the system clocks.
Field Manager II Field Name Enter
1 ACD Split [I
NTUITY AUDIX system split #]
2 Member 1
3 Member Extension [extension number of split member 1]
Table 3-2. Data Link Procedure Overview
Step Procedure Field Manager II Field Name Enter Press
1 275 Word 1 15 Tandem Tie Trunk 1
16 Trunk-Trunk Calling 1
17 DCIU 1 Change
2 275 Word 3 8 Local Switch Number record #
10 Call control FRL record # Change
Continued on next page
ADD EXECUTE