1. FRL should match the Call Control FRL. Check Proc275, Word 3, Field 10. If the FRL is 0 and AMIS
and outcalling are to be used, the Call Control FRL may need to be increased.
8 026 Word 1 1 ACD Split split #
2 Split Size # of I
NTUITY AUDIX
system ports in one
of these increments
— 16,32,48,64
4 Queuing Trunk Group trk grp #
8 Inflow Level 0
9 Hunt Type 0
10 Split Type 2
11 Machine Number machine # Add
9 001 Word 1 1 Primary Extension ext #
2 Associated Extension I
NTUITY AUDIX
system ext # (used
if vectoring not
used)
Add
10 026 Word 2 1 ACD Split split #
2 Supervisory Extension ext #
3 Queue Directory
Number
I
NTUITY AUDIX
system ext # (leave
blank if vectoring
used)
Add
11 026 Word 3 1 ACD Split split #
2Member 0 - 63 Next
Data
3 Member Extension ext # for split mbr 0 Add
Table 3-1. Voice Port and ACD Split Procedure Overview — Continued
Step Procedure Field Manager II Field Name Enter Press