011 Word 1
Administer the criteria, principle don’t answer interval, and coverage points of a
call coverage group.
Press and .
Add the Subscriber Stations
After you administer the call coverage path, you must add or change the
subscriber stations. Each subscriber station must contain the correct information
for the Lucent I
NTUITY system to operate. For a list of subscriber extensions, see
I
NTUITY
New System Planning
, 585-310-603.
1. If using Call Vectoring, enter the Call Coverage Group Number.
2. If you enter, a second appearance of a number to answer on
multiappearance voice terminals will appear when the first appearance is
active.
If you enter a nonzero number in this field, this field will send subsequent calls
to coverage when the first appearance is active. A nonzero value will speed
up testing.
3. This shows that the last point is an ACD split rather than an extension. If Call
Vectoring is used, assign a Vector Directory Number (VDN) as the final
coverage point.
4. To simplify testing, make INTUITY AUDIX system split the first and only point in
the coverage path.
Field Manager II Field Name Enter
1 Call coverage Group [group split #]
1
2 Extension Active
0 or 1
2
7 Coverage Point Indicator 1
3
7 ACD Split Indicator 1
3
8,9, or 10 Coverage Point;[INTUITY AUDIX
system split]
4