System information
Lucent INTUITY System Administration for Switch
Integration
5-4 Issue 1 October 1997
10. Press to update the system with the changes you entered.
The system displays the following message Update successful to
indicate that the switch link is resetting.
11. Press to exit the Switch Interface Administration screen and return
to the Lucent I
NTUITY System Main menu (Figure 5-1).
12. You have completed the Lucent I
NTUITY system administration required for
a DCIU switch integration. Continue with Chapter 6, ‘‘Acceptance Test
Administration’’.
Administer the Lucent INTUITY System
for a DCS Network Switch Integration
Use the instructions in this section to administer the Lucent INTUITY system for a
DCS network switch integration. Do not perform the procedure in this section
unless you have a DCS network already up and functional. See the ‘‘Administer
the Lucent I
NTUITY System for a Non-DCS Switch Integration’’ above for
instructions on administering the Lucent I
NTUITY system without DCS.
!
CAUTION:
When you update the DCIU Interface Administration window, the Lucent
I
NTUITY system resets the DCIU switch link.
1. Access the Lucent I
NTUITY system main menu (Figure 5-1).
NOTE:
If you need instructions for logging in to the system and accessing
the Lucent I
NTUITY system Main menu, see the document:
I
NTUITY
Messaging Solutions Administration
.
2. Select Switch Interface Administration.
The system displays the DCIU Interface Administration window (Figure
5-2).
When you access the screen, the cursor appears in the Extension
Length field. (The Switch Link Type and Switch Release fields are
display only.) When the switch integration software was installed, the
switch link type and switch release information was entered. You cannot
change the information in these fields. For more information on the
installation process, see the installation document for your Lucent I
NTUITY
system.
3. Enter an extension length of, 3, 4, or 5, of the dial plan in the Extension
Length field. See ‘‘Worksheet B: Voice Port Extensions and Names’’ in
Chapter 2, ‘‘Switch Integration Planning’’ to determine the extension
length.
SAVE