Instruction manual
HARDWARE AND SOFTWARE DETERMINATION
Data Modules
Data modules are communications devices that provide an interface between the digital switch,
Data Terminal Equipment (DTE), and Data Communications Equipment (DCE). Data modules
transmit and receive data, converting between the system’s Digital Communications Protocol
(DCP) and the following interfaces: EIA-232C, RS-366, RS-449, V.35, and a Category A coaxial
interface.
Figure 2 shows some of the ways modules can be connected in a Local Data Endpoint configura-
tion. Figure 3 shows some of the ways modules can be connected in a Remote Data Endpoint
configuration.
To protect existing investments, in-place equipment that performs the same function as DEFIN-
ITY Generic 1 or Generic 3 data modules may be used.
The following system data modules are covered:
Digital Terminal Data Module (DTDM)
Z702AL1-DSU Data Module Base
Modular Trunk Data Module (MTDM)
Modular Processor Data Module (MPDM)
7400A Data Module
7400B Data Module
7500B Data Module
3270 Data Module
Z3A Asynchronous Data Unit (ADU)
Pooled Modem
Digital Terminal Data Module (DTDM)
The DTDM provides synchronous or asynchronous voice and data communications to 7403D and
7405D digital voice terminal users who have a terminal or personal computer. The DTDM and
voice terminal integrate data and voice into the DCP for the switch.
Z702AL1-DSU Data Module Base
The Z702AL1-DSU Data Module Base provides the DCE interface connection between a 7407D
voice terminal and data terminals. The module provides full-duplex asynchronous operation only.
The module and 7407D voice terminal integrate data and voice into the DCP for the switch.
55