Instruction manual

FEATURE DETERMINATION
TABLE B
(continued).
Features Requiring Additional Hardware and/or Software
Hardware and/or Actual
Feature Software Hardware and/or
Required Software Needed
Power Failure Transfer One emergency transfer panel per five or
six trunks assigned to Power Failure
Transfer, depending on which of the two
panels is used.
808A Panel—Serves up to five power
failure transfer terminals. Provides
automatic ground start or loop start and
‘‘restore after busy’’ feature.
PORTA SYSTEMS Model 574-5
Panel—Serves up to five power failure
transfer terminals. Provides automatic
ground start or loop start.
Property Management
System (PMS)
Either a TN726 Data Line circuit pack with
an ADU or a data module and port on a
TN754 Digital Line circuit pack. Printer
required.
Queue Status Indication One port on a TN746 Analog Line circuit
pack for each auxiliary queue warning lamp
(such as a 21C-49).
Requires ACD software.
Recorded Announcement Announcements can be either analog or
integrated. Each analog announcement
requires announcement equipment (Cook
Electric 213300 Single Channel or Cook
Electric 213400 Multi-Channel) and one port
on a TN746 Analog Line circuit pack. For
customized recorded announcements, a
model HQD614B Recorder/Announcer
manufactured by the Audichron Company
can be used. Each integrated announce -
ment, accessed by a call, requires one port
on a TN750 Announcement circuit pack. Up
to 64 announcements can be recorded on
the TN750.
24