Communications System Owner Manual
Table Of Contents
- Table of Contents
- ABOUT THIS DOCUMENT
- 1. INTRODUCTION TO CONNECTIVITY
- 2. COMMUNICATION SYSTEM NETWORKING (em AN OVERVIEW
- 3. TANDEM TIE TRUNK NETWORKS
- 4. MAIN-SATELLITE/TRIBUTARY (MS/T) NETWORKS THROUGH THE UDP OR MULTIPREMISES PACKAGES
- 5. ELECTRONIC TANDEM NETWORK (ETN) THROUGH THE ETN AND PNA PACKAGES
- 6. DISTRIBUTED COMMUNICATIONS SYSTEM (DCS)
- 7. DATA CONNECTIVITY - AN OVERVIEW
- 8. DATA COMMUNICATIONS CAPABILITIES
- 9. DATA COMMUNICATIONS CONFIGURATIONS
- A. RELATED DOCUMENTS
- B. SYNCHRONIZATION OF DIGITAL FACILITIES
- THE NEED FOR SYNCHRONIZATION
- SYNCHRONIZATION HIERARCHY
- CHANGES TO THE SCS SOFTWARE MADE AVAILABLE VIA SOFTWARE PATCHES
- NETWORK SYNCHRONIZATION AND ENGIINEERING
- AVAILABILITY OF SYNCHRONIZATION SOURCES
- CONCLUSIONS ON SYNCHRONIZATION
- USE OF GENERIC 2 AS A SYSTEM CLOCK REFERENCE
- USE OF GENERIC 1 AS A SYSTEM CLOCK REFERENCE
- C. TRUNKING TERMS AND CAPABILITIES
- D. COMMUNICATIONS PROTOCOLS
- E. LEAD DEFINITIONS
- F. NETWORKING FEATURES - AVAILABILITY MATRIX
- ABBREVIATIONS
- GLOSSARY
- INDEX
COMMUNICATION SYSTEM NETWORKING — AN OVERVIEW 2-19
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
Table 2-3. Networking Feature Parameters
_ ____________________________________________________________________________________
DIMENSION SYSTEM 85 SYSTEM 75 DEFINITY
FEATURE PBX
_ ________________________________________________________________________
FP8 R1 R2 R1 G1 G2
_ ________________________________________________________________________
Iss 1 Iss 3 - V1 V2 V3 V4 V1 V2 V3
_ _______________________________________________________________________
_ _______________________________________________________________________
ACA:
# Char in
Display 4 4 4 4 4 4 4 0 40 40 40 4
_ ____________________________________________________________________________________
AAR:
# of Patterns 180 255 180 255 255 640 640 0 254* 254* 254* 640
# of Trk Grps/
Pattern 4 16 4 4 4 16 16 0 6 6 6 16
_ ____________________________________________________________________________________
ARS:
# of Patterns 64 64 64 64 64 64 64 16 254* 254* 254* 64
# of Trk Grps/
Pattern 10 16 16 16 16 16 16 6 6 6 6 16
# of 6-Digit
Translations 64 128 32 64 64 160 160 4 32 32 32 160
# of Patterns/
6-Digit Trans 4 4 4 4 4 10 10 16 12 12 12 10
# of Access
Codes 2 2 2 2 2 2 2 1 1 2 2 2
_ ____________________________________________________________________________________
Auth Codes:
# of Codes 9000 9000 9000 9000 9000 90000 90000 0 0 5000 5000 90000
# of Digits 4-7 4-7 4-7 4-7 4-7 4-7 4-7 0 0 4-7 4-7 4-7
_ ____________________________________________________________________________________
CAS:
# RLTs Out (Br) 16 16 16 16 16 16 16 0 16 16 16 16
# RLTs In (Mn) 110 110 110 110 110 110 110 0 0 200† 200† 110
# RLT Grps
At Main 40 40 40 40 40 40 40 0 0 99‡ 99‡ 40
_ ____________________________________________________________________________________
FRL:
# of FRLs 8 8 8 8 8 8 8 8 8 8 8 8
_ ____________________________________________________________________________________
IXC Access:
# of Digits
Sent 0 24 0 0 0 24 24 0 40 40 40 24
# of Digits
Inserted 0 20 0 0 0 20 20 0 36 36 36 20
# of Digits
Deleted 0 7 0 0 0 7 7 0 11 11 11 7
_ ____________________________________________________________________________________
* The number of patterns are shared between AAR and ARS.
† Maximum number of trunks per system (all types).