Specifications

Table Of Contents
CALLMASTER Voice Terminals
13-16 Issue 11 December 1999
4-WIRE installations MUST ONLY have PBX connections on pair 2 and pair 3 and, if
necessary, auxiliary power must be connected to pair 4.
2-WIRE installations MUST ONLY have PBX connections on
pair 1 and, if necessary,
auxiliary power must be connected to pair 4.
Wiring Note for the CALLMASTER VI
All wiring between the DEFINITY ECS and the CALLMASTER VI, including the
line cord, must consist of twisted pairs. Twisted-pair wiring makes lines less
sensitive to crosstalk. The line cord must be a D8W, which consists of four twisted
pairs, or a Lucent Technologies-approved equivalent.
Distance Limitations
The maximum allowable distances the CALLMASTER voice terminals can be
located from the DEFINITY G1, G2, and G3, DEFINITY ECS, System 75, or
System 85 cabinet is shown in the table below.
NOTE:
The 602 CALLMASTER can be connected to any of the switches listed
directly above. However, the CALLMASTER II and CALLMASTER III are
only supported when connected to a DEFINITY G3. The CALLMASTER IV
is supported only when connected to a DEFINITY G3V3.
Notes:
These ranges can be extended to 5,000 feet (1524 m) for 24 AWG wire and 4,000 feet
(1219 m) for 26 AWG wire with the use of a Data Link Protector. Refer to EXPOSED
PORT PROTECTION
.
In 2-wire installations, the CALLMASTER III and CALLMASTER IV can be connected to a
TN2181 port board.
Table 13-2. Distance Limitations for the CALLMASTER II, III, and IV Voice
Te rm in al s
(See Note above for a list of supported connections for each set)
System Port Board
Nominal Maximum Range in
Feet (Meters) (See Note)
24 AWG 26 AWG
DEFINITY G2
System 85
SN270B
TN754
3,400 (1,034)
3,400 (1,034)
2,200 (671)
2,200 (671)
DEFINITY G1
and G3,
DEFINITY ECS,
and System 75
TN754 3,400 (1,034) 2,200 (671)