Instruction manual

SYSTEM BACKUP FOR DEFINITY G3vs
12.
13.
14.
15.
Request is incompatible with currently running operations
Indicates the storage system is in use.
Response: Try again later.
Saved copy of announcements is unusable
The file on the Memory Card is unusable.
Response: Use another backup card if you have one. Instances such as
this illustrate the importance of having backup cards.
Saved copy of translations is unusable
The copy of the translations on your Memory Card is faulty.
Response: Run the save translations command again.
Transmission problem; please try later
There IS a problem communicating with the announcement board.
Response: Check to see that a data module, “Type: announcement” has
been administered correctly. Use the list data-module command to
determine if the data-module “Type: announcement” is administered. The
data module “Type: announcement” is administered using the add data-
module <extension_number of data module type announcement>. If
adding or checking the data module type announcement, verify that the
“Board:" field is translated with network, carrier and slot where the
announcement circuit pack is installed. Check that the Class of
Restriction (COR) of the data module “Type announcement” is allowed to
terminate calls from the data-modules “Type: netcon.” The data modules
“Type Netcon:” with their COR can be identified by using the “list data-
module” command. Note the netcon data modules must also have their
COR’s translated that they can call each other.