Instruction manual
HARDWARE AND SOFTWARE DETERMINATION
TABLE J. Voice/Data Terminal Quantities
Type
Model
Quantity
Orderable With G3
2500 Series
2500DMGC
2500YMGK
Single-Line Analog¹
510A
7102A
8102
8110
7303S²
Multi-Appearance Hybrid
7305S²
7401D
7403D²
7404D²
7405D²
7406D
7407D
7410D
Multi-Appearance Digital³
7434D
7401 Plus
7406 Plus
7407D Enhanced
7407 Plus
7410 Plus
7444 Plus
CallMaster®
7505
ISDN-BRI®
7506
7507
8503T
1. When used as on-premises, out-of-building stations, lightning protection is required. A carbon block, a wide-gap gas
tube, or an equivalent solid-state device is required at each end of the interbuilding cable.
2. When used as on-premises, out-of-building stations, lightning protection is required. An ITW LYNX protector
(LP2-100-068) or 4C3S-75 protector is required at each end of the interbuilding cable.
3. These terminals are no longer orderable. They have been Manufacturer Discontinued.
75