Instruction manual
SYSTEM PARAMETERS
TABLE G (continued).
System Parameters
Item
G1
G3i
G3r
Attendant Service
Other Access Queues
Max. Number of Queues
1
1 [12]
12
Max Number of Queue Slots (3) 50 50 [80] 80
Size range of Resewed Queue
NA
NA [2–75] 2–75
Reserved Queue Default Size
NA
NA [5]
5
Queue Length
30 .
30 [80]
300
Switched Loops/Console
6
6
6
ARS/AAR
AAR/ARS Patterns (Shared) 254 254
640
ARS/AAR Table Entries
(NPA, NXX, RXX, HNPA, FNPA)
NA
2,000
2,000
Choices per RHNPA Table
12 12 12
Digit conversion Entries
180
300 300
Digits Deleted for ARS/AAR
11
18 18
Digits Inserted for ARS/AAR 36 36 36
Entries in HNPA& RHNPA Tables 800
1,000
1,000
FRLs
8
8
8
Inserted Digit Strings (4)
NA
1,200
3,000
Patterns for Measurement
Shared Patterns for Measurement
20
20 25
RHNPA Tables
32 32 32
Routing Plans
8 8
8
Toll Tables
4
32
32
Entries per Toll Table
800 800
800
Trunk Groups in an ARS/AAR Pattern
6 6
16
UDP (Entries)
240
240
50,000
TOD Charts
8
8
8
ASAI
Active Controlling Associations
NA
2,000
3,000
Call Controllers per Call
NA
1
1
Call Monitors per Call
NA
14
14
Extension Controllers per Station Domain
NA
2
2
Max, Simultaneous Call Classif.
NA
40
100
No. of ASAl Links
NA
8 8
Notification Requests
NA
170
460
Simultaneous Active Adj.Controlled Calls
NA
300 3,000
Switch to Adjunct Associations
NA
127
127
(3) “Maximum number of queue slots” is referred to as “emergency access queue
length” in G1.
(4) This is the number of available 12-character inserted-digit-strings available for
AAR/ARS preferences.