Instruction manual

CONFIGURATION GUIDELINES
TABLE B (continued).
Multicarrier Cabinet—Universal Port Slots and Associated Circuit Packs
7.
Only one TN750B Announcement circuit pack may be assigned in the System,
Assign in Control Carrier 1A when possible.
8.
One TN771 B required in a duplicated system.
9.
Required when connecting to an external Stratum 3 clock.
10.
Use TN465 in G3i-Global where administrable timers and 16 kHz PPM are
required.
11.
Use TN479 in G3i-Global where a 24 volt limit or Japanese ring cadence is
required.
12.
Use TN429 in G3i-Global where Japanese signaling scheme is required.
13.
Use TN464 in G3i-Global where 32 channels and 2.0 Mb communications are
required.
5. Using the hardware Configuration Layout record, assign circuit packs to port slots on all
Port Assignment Records.
6. Identify how many ports are available on each type of circuit pack using Table B. If a cir-
cuit pack contains less than eight ports, strike out (do not use) the unavailable slots on
the Port Assignment Record associated with that circuit pack.
Some of the System forms require port information. When competing such a form, first
determine the type circuit pack that is required. Obtain the Port Assignment Record and
select the next available vacant port on the appropriate circuit pack. Then, complete the
following Port Assignment Record items as required:
Jack #— to be completed by the installation technician. Used to denote the physical
location of the jack.
Extension Number— enter the extension number.
old—enter the old extension number to be replaced
new—enter the new extension number
Bldg., Flr., Rm.— enter the identifying information for the location of the voice terminal,
data terminal, etc.
Voice Terminal or Equipment Type/Color— enter the terminal or equipment informa-
tion.
Voice Terminal Adjunct— enter adjunct equipment associated with the terminal, for
example, speakerphone, headsets, etc.
15