Instruction manual

CONFIGURATION GUIDELINES
Obtain sets of blank records for all control and port carriers to be used, then complete the follow-
ing:
1. With a set of records for a carrier, enter the following carrier lD as applicable after the
“CARRIER” entry at the top of the Port Assignment Record form.
Enter 1A for the Control Carrier (J58890AH-1).
Enter 1 B for the Duplicated Control Carrier (J58890AJ-1).
Enter 2A (EPN 1) or 3A (EPN 2) for the Expansion Control Carrier (J58890AF-1).
Assign a letter (B, C, D, or E) to all records for each Port Carrier (J58890BB-3).
Use the letter as noted on Figures 1, 2, or 3 for the Port Carrier location in the
cabinet configuration.
2. Following the “CABINET” entry at the top of the record, enter the cabinet type as either
PPN, EPN 1, or EPN 2 as applicable.
3. Repeat these steps to complete records for all Control and Port Carriers used in the Sys-
tem.
4. Assign port circuit pack slot numbers on the sets of records as follows (refer to Table B
for circuit pack port slot availability and associated notes where applicable):
For Control Carrier 1A, begin with slot number 1 and number through 9.
For Control Carrier 1 B, begin with slot number 1 and number through 9.
For the Expansion Contd Carrier 2A for EPN 1 or 3A for EPN 2, begin with slot
1 and number through 19.
All Port Carriers (B, C, D, E) slots should be numbered 1 through 20.
13