Specifications
2.
Install the voice messaging system module in the first available slot to the right
of the last installed 206 or 400 module. Do not install the voice messaging
system module in the first slot of the PARTNER Plus system control unit or
the PARTNER
II
or PARTNER 48 system primary carrier.
NOTE:
The voice messaging system module should always be installed after the
206 and 400 modules to ensure consecutive extension numbering. If the
control unit is upgraded with more 206 or 400 modules, the voice
messaging system module should be removed, the new modules should
be installed, and the voice messaging system module should be replaced
in the first available slot after the 206 and 400 modules, The VMS Hunt
Group Extensions and Transfer Return Extensions should be
reprogrammed (see page 4-2 and 4-3).
Push slowly but firmly in the center of the module until the module locks
into place, and is attached to the rear of the backplane. Do not force the
module. If it does not insert easily, remove the module, clear any
obstruction, and reinsert it.
3.
Refer to Figure 2-1, then record the extensions associated with the PARTNER
MAIL VS module on Form B1 of the System Planner for the
communications system.
Figure 2-1. Voice Messaging System Extensions
2-2 Installation