Specifications
Environmental
■ Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
Requirements—
■ Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded
Control
Unit
electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords
■ Mount the Expansion Carrier at least 6" (15.2 cm) and not more than 24" (61 cm) away from the
Primary Carrier
■ Operating temperature 32° to + 104°F (0° to + 40°C), not in direct sunlight
■ Humidity 15%-90%, noncondensing
■ For proper ventilation and easy replacement of modules, provide at least 6" (15.2cm) clearance
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
■ Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
■ U.S. and Canada: 90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at
Requirements
15 Amps: Other countries: 180–264 VAC, 50-60 Hz, fused at 10 Amps
■ Outlet must not be controlled by an on/off switch
■ Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation
material and thickness to the grounded and ungrounded branch circuit supply conductors,
except that it is green with or without one or more yellow stripes, is to be installed as part of the
circuit that supplies the product or system.
B. The grounding conductor mentioned in item A is to be connected to ground at the service
equipment.
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
grounding type, and the grounding conductors serving these receptacles are to be connected
to earth ground at the service equipment.
Safety
■ U. S.: Meets UL 1459 Issue 2
Requirements
■ Canada: Meets CSA C22.2, 225
Government
■ U.S.:
FCC Part 68
Approvals and
FCC registration number (U.S.): AS5 USA-61630-KF-E
Local Phone
FCC Part 15 Class A
Company
REN (outside line jack): 0.9A per line jack
Information
Jack type: RJ11C
Loop start lines
■ Canada:
IC CP01, Issue 7
IC registration number (Canada): 230 3756A
IC CS03, Issues 6 & 7
Load Number = 7
Loop start lines
A-2 Specifications