Specifications

Specifications
A
Capacities
Voice Channels: 2
Max. Mailboxes:
10 (or 20 with Mailbox Expansion Card)
Voice Storage:
120 min. (or 220 min. with Mailbox Expansion Card)
Total Number of Calls Supported During Peak Usage Hour:
Call Connect
Time* Calls
0.5 minute
25
1 minute
12
1.5 minute
8
Dimensions
PARTNER MAIL VS:
11”(D) x 17”(H) x 1.5”(W) or 27.9 x 43.2 x 3.8 cm
4.3 lbs or 2.0 kgs
and Weights
Mailbox Exp. Card: 3.4”(D) x 2.1”(H) x 0.2”(W) or 8.6 x 5.3 x 0.5 cm
.07 lbs or 32 grams
(approx.)
Electrical
Specifications
15 Watts (52 BTU/hour) per PARTNER MAIL VS module during normal and maximum power
consumption
Maximum current 0.13 Amps
Configuration stored on hard disk drive
Battery backup compatible
Processors
68000 microprocessor, 256Kbytes RAM, 256Kbytes ROM
Specifications
Voice encoding method: Regular Pulse Excitation—Long Term Prediction (RPE—LTP) Linear
Predictive Coder
Digital Signal Processor (DSP), 16 bit
Environmental
Requirements—
Control Unit
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded
electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords
Mount the Expansion Carrier at least 6”(15.2 cm) and not more than 24” (61 cm) away from the
Primary Carrier
Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight
Humidity 15%–90%, noncondensing
For proper ventilation and easy replacement of modules, provide at least 6"(15.2cm) clearance
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
*
Call connect time is an average for all calls to the PARTNER MAIL VS system including Tutor, Automated Attendant
Service, Call Answer Service, and Voice Mail Service. This information assumes a 2% probability of system blockage.
Specifications A-1