Instruction manual
Trunk group reports
Issue 3 July 2001
67Send feedback: document@avaya.com
reports
Current trunk group status
The Trunk Group Status report displays a current view of the load
on various trunk groups by showing the number of calls waiting
for service. This report shows data for 60 trunk groups at a time,
but you can start the display at any number you want. For
example, let’s display trunk groups 5 and up.
To display the Trunk Group Status report:
1. Type
monitor traffic trunk-groups 5 and press RETURN.
The Trunk Group Status report displays trunk groups 5
through 64.
This report shows only administered trunk groups.
2. Press
CANCEL to return to the prompt.
Least used trunks
The Trunks Lightly Used Measurements report lists the five trunk
members with the lowest number of calls carried for each trunk
group. The system shows trunk lightly-used data for the last hour,
current day, or previous day. Let’s display this report for today.
To display the Trunks Lightly Used Measurements report for
today:
1. Type
list measurements lightly-used-trunk today and
press
RETURN.
If the trunk member in the Calls Carried field has an unusually
low number of calls compared to other trunk members, use
Facility Test Calls to determine how a specific trunk member is
functioning. To monitor a particular trunk group, use Automatic
Circuit Assurance (ACA). Refer to DEFINITY System’s Little
Instruction Book for basic diagnostics for more information.