Instruction manual

Using reports
66 Issue 3 July 2001 Send feedback: document@avaya.com
To monitor trunk group 12 for the next hour:
1. Type
change meas-selection trunk-group and press
RETURN.
The Trunk Group Measurement Selection screen appears.
2. Move to a measurement field and type
12.
3. Press
ENTER to save your changes.
The system records the activity of trunk group 12 for the
next hour.
4. Type
list measurements trunk-group hourly 12 and
press
RETURN.
The Trunk Group Hourly report displays data from the
previous hour.
Out-of-service trunks
The Trunk Outage Measurements report lists the trunks that were
out-of-service during a selected period of time. This report may
include up to five out-of-service trunks and lists how many times
each trunk was out during the specified time. The system records
trunk-outage data for the last hour, current day, and previous day.
To display the Trunk Outage Measurements report for yesterday:
1. Type
list measurements outage-trunk yesterday and
press
RETURN.
If there are no outages, the form is blank.
The Trunk Outage Measurements report samples trunk activity
once per hour. Therefore, if the report covers several hours, but
indicates only a small number of outages, a trunk member may be
providing intermittent service.