User`s guide
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 17
May 2002
Using the ADAP Command Line Language
11-10Command Line Commands
11
-r Release number flag. Must be followed by the release
number, which identifies the version of the DEFINITY
AUDIX system (D-r3.2, D-r3.1, D-r3.0, D-r2.0, or D-r1.0),
the R1 AUDIX system (r1v8, r1v7, r1v6, r1v5, r1v4_5,
r1v4, r1v3, r1v2), or the I
NTUITY AUDIX system
(I-r5.0, I-r4.0, I-r3.3, I-r3.2, or I-r2.0) with which it is
communicating. The default for DEFINITY AUDIX is
D-r3.2. The default for I
NTUITY AUDIX is I-r5.0.
When accessing an R1 AUDIX System or a DEFINITY AUDIX System other
than release 3.2, you may want to change the default release value to
correspond to the release of that AUDIX system. This allows you to enter
retrieval and modify commands for this AUDIX system without using the
-r release option. Prior to executing retrieval and modify commands, set the
AUDIX_RELEASE environment variable to the release value you want by
entering one of the commands listed below:
When accessing a DEFINITY
AUDIX System
When accessing an
R1AUDIX System
set AUDIX_RELEASE=D-r1.0 set AUDIX_RELEASE=r1v2
set AUDIX_RELEASE=D-r2.0 set AUDIX_RELEASE=r1v3
set AUDIX_RELEASE=D-r3.0 set AUDIX_RELEASE=r1v4
set AUDIX_RELEASE=D-r3.1 set AUDIX_RELEASE=r1v4_5
set AUDIX_RELEASE=r1v5
set AUDIX_RELEASE=r1v6
set AUDIX_RELEASE=r1v7
set AUDIX_RELEASE=r1v8
To clear this environment variable, enter the following command:
set AUDIX_RELEASE=
without a release value. This restores D-r3.2 as the default release value.
Similarly, when accessing an I
NTUITY AUDIX system other than release I-r5.0,
you may want to change the default release value to correspond to the release
of that AUDIX system. This allows you to enter retrieval and modify commands
for this AUDIX system without the need to use the -r release option.