User guide
Acceptance Checks
4-4 Issue 1 September 1995
5. Press (F7) to display the second page of System-Parameters
Maintenance screen
.
If Worksheet C-10
Set Up Alarm Origination
, indicates that alarm origination is to be
activated through the switch only, enter n in the Alarm Origination Active? field. If
either audix only, or audix & switch, is indicated on Worksheet C-10, enter y in the
Alarm Origination Active? field.
6. Ask the INADS personnel to login and display the System-Parameters Maintenance
screen. The following steps should be completed by INADS personnel
:
a. INADS checks that the login is successful.
b. INADS checks that the Product Identification Number on the
System-Parameters Maintenance screen is correct
.
c. INADS enters the test alarm-origination command, terminates login, and
hangs up.
d. INADS checks the appropriate trouble ticket. The trouble ticket should show
INADS, n, MINOR in the description field to indicate that a minor off-board
alarm was reported to INADS. There may be additional text in the
description field if other resolved alarms were reported.
e. INADS makes a second call and login to the DEFINITY AUDIX system and
checks the error log to verify that there are no problems.
f. INADS terminates login and hangs up.